Odme S3000 Manual Pdf __exclusive__ 〈OFFICIAL — Breakdown〉
: Manages the flow of samples and provides an automatic back-flushing sequence . Operational Procedures ODME SEIL – SERES S 3000 - beMPC
: Triggers when oil content exceeds 15 PPM (clean ballast), when the 30 L/NM limit is reached, or in cases of system failure (e.g., no sample flow, printer failure). Primary System Components
: Features a 40x4 character LCD display, membrane keypad, and a built-in 24-column matrix printer for record-keeping. odme s3000 manual pdf
The ODME S3000 serves as the central control for ballast and effluent discharge on oil tankers above 150 gross tons.
: Includes a Pitot-tube type probe and DP transmitter to calculate discharge rates. : Manages the flow of samples and provides
: Uses a scattered I.R. light method with multi-cell sensors (Si-photodiode) to detect oil content in parts per million (PPM).
The (Oil Discharge Monitoring Equipment) is a critical maritime safety system manufactured by KSB Seil (formerly Seil Seres). It is designed to monitor and control the discharge of oily water mixtures from tankers into the sea, ensuring strict compliance with MARPOL Annex I and IMO Resolution MEPC.108(49) . System Overview and Compliance The ODME S3000 serves as the central control
: Fully compliant with IMO/MARPOL MEPC 108(49) and MEPC 240(65) for the monitoring of crude oils, "black" and "white" products, and bio-fuel blends.
: Features a self-cleaning design to minimize maintenance and ensure accuracy.