Squeeze the rubber safety edge firmly and release; the status LEDs (D4 and D5) should switch off briefly to confirm detection.
The Crawford CDM9 complete set typically includes a 0.37 kW motor, approximately 60 Nm of torque, and a 10-meter cable for connection between the motor and the control box. : 340 x 230 x 140 mm.
: Standard CDM9 supports doors up to 400 kg; the HD version handles up to 800 kg. Supply Voltage : 230V AC, single phase, 50/60Hz. Operating Temperature : -20°C to +55°C. Mechanical Installation Steps crawford cdm9 950 installation manual
: Disengage the door and position it approximately 1.5 meters above the floor before engaging the operator again.
The ECS 950 control unit uses several internal cards, including the (standard functions) and the manoeuvring card , which features status LEDs for the stop circuit and limit switches. Squeeze the rubber safety edge firmly and release;
The ECS 950 Service Tool Manual identifies key issues through a service lamp and error codes.
: Any fault in the safety edge will force the door into "Hold-to-run" mode for closing as a safety precaution. : Standard CDM9 supports doors up to 400
Use the "Hold-to-run" command (pressing the Up/Down buttons) to bring the rubber sealing edge to the 1m mark.
: Turn the installation switch ( SW1 ) to the ON position. Calibration : Mark a "1m position" on the door frame.
The door will then move slowly by impulse operation to the floor and reverse to the fully open position to set the limit points.